| ABKW | OVERALL HEIGHT | 3.750 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 2.250 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 1.500 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 3.375 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.750 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.000 INCHES NOMINAL |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | 110.0 HERTZ 1ST LOW PASS FIRST FUNCTION |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | 190.0 HERTZ 2ND LOW PASS SECOND FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 100.0 KILOHMS 1ST LOW PASS FIRST FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 100.0 KILOHMS 2ND LOW PASS SECOND FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 100.0 KILOHMS 1ST LOW PASS FIRST FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 100.0 KILOHMS 2ND LOW PASS SECOND FUNCTION |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 2ND LOW PASS SECOND FUNCTION |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 1ST LOW PASS FIRST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TURRET INPUT FIRST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TURRET GROUND THIRD FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TURRET OUTPUT SECOND FUNCTION |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 80.00 HERTZ 1ST LOW PASS AND 140.00 HERTZ 1ST LOW PASS AND 240.00 HERTZ 1ST LOW PASS AND 480.00 HERTZ 1ST LOW PASS FIRST FUNCTION |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 80.00 HERTZ 2ND LOW PASS AND 300.00 HERTZ 2ND LOW PASS AND 500.00 HERTZ 2ND LOW PASS AND 1.00 KILOHERTZ 2ND LOW PASS SECOND FUNCTION |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 80.00 HERTZ 1ST LOW PASS AND 140.00 HERTZ 1ST LOW PASS FIRST FUNCTION |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 80.00 HERTZ 2ND LOW PASS AND 300.00 HERTZ 2ND LOW PASS SECOND FUNCTION |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 NOMINAL 2ND LOW PASS AND 40.0 NOMINAL 2ND LOW PASS SECOND FUNCTION |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 NOMINAL 1ST LOW PASS AND 40.0 NOMINAL 1ST LOW PASS FIRST FUNCTION |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |